Therefore it can much better simulate the operating conditions of the devices tested. Basic accuracy for all RLC measurements is 0.1% with test frequencies of 20 Hz up to 10 MHz. In Multi- Step Mode, the unit provides the ability to perform up to 30 different measurements on one component and it has a Pass/Fail function with an acoustic alarm and many parameter options to set. Up to 64 test programs can be stored in non-volatile memory. The characteristics of the component under test can be displayed on an LCD graphics screen (320×240 pixels), with either the voltage range or the frequency sweep on the horizontal axis.
The unit comes with RS-232 and GPIB interfaces for remote control and transfer of test data to a remote computer for further analysis. Various optional test leads and fixtures are available for different component types and 2/4 wire measurements.