These modules are compliant with DOSA 16th brick footprint and interface standards. These converters have a wide input voltage range of 18-36 or 36-75V DC and provide 2250V DC input to output isolation.
The CPT 2:1 input series meets EN 60950 basic insulation requirements and is UL94 V-0 flammability rated. The module complies with all of the typical industry requirements including no load operation, two times nominal input voltage transient and pre-biased load startup.
Other features include: fixed-frequency operation, auto-restart OVP, OCP and OTP protections, UVLO, remote sense and +10 or -20% output voltage trim using industry standard equations. Remote ON/OFF is standard with positive or negative logic options available.
The modules feature a standard 16th brick pinout with dimensions of 1.3×0.9” (33.02×22.86mm.) They have a maximum height of 0.404″ (10.3mm) which accommodates tight card spacing with minimal airflow blockage of downstream components.