Its proven touch protection design allows the probe to be used in CAT III environments up to 1000 V and CAT IV up to 600 V, in accordance with the IEC/EN 61010-031 standard.
The highly flexible 120 cm long double-insulated lead is terminated in a fully insulated BNC plug which includes an integral compensation circuit. This can be adjusted between 12 pF and 25 pF to match a variety of oscilloscope types. A 2 mm safety socket in the probe allows connection of a reference lead.
The Isoprobe III HP has a 100:1 dividing ratio, with a frequency range of 1.1 kHz to 35 MHz (3dB). Input capacitance is as low as 8 pF with a rise time of less than 10 ns.
The probe is available separately or it can be supplied with an accessory set including a push-on hook clip, reference lead with crocodile clip, push-on insulation sleeve and colour coded clips for easy probe identification.