PIM test lead optimised to 4GHz

A PIM test lead designed for use with factory PIM analysers where there is a requirement to test antennas and components has been introduced by Huber + Suhner. The lead can also be used in the field with portable PIM analysers. Users will include PIM equipment manufacturers, network installers and operators as well as T&M specialists.  

The PIM test lead features a highly flexible, rugged and reliable construction and the company has designed the TL-P to be very durable with more than 2000 mating cycles achievable under normal working conditions.

Optimised up to 4GHz, the Huber+Suhner TL-P PIM test lead is equally suitable for Return/Loss (RL) testing.

Available in cable lengths of 1.5 or 3m, key values include a PIM figure of ≥ -117dBm (tested to IEC62037-2), return loss (up to L = 3m) of ≤20dB at 4GHz and attenuation up to 0.90dB/m at 3GHz. The TL-P can handle power levels to ≤ 560W at 1GHz and has a shielding effectiveness greater than -120dB.

All test lead assemblies are 100% tested for PIM, return loss and attenuation and come with a PIM test report and connector protection caps.