The three individual modules plug into a 19”, 2U rack which can be used in a 19” cabinet of various heights (typically 1620mm, 1798mm and 2020mm). High system efficiency ensures a low level of heat dissipation allowing the unit to be forced air cooled, with the cooling air separated from the electronics.
Outline specifications of the Powerstax TVR3001 include; up to 3000W of output power, wide input range from 11 – 36Vdc suitable for MIL-STD-1275, step-up and step-down DC-DC conversion, standard output voltages 12V (200A), 15V (200A), 24V (126A), 28V (102A), 48V (63A), high efficiency – typically 86%, reduced system heat dissipation, comprehensive protection, remote on/off, I²C temperature sensor and operating temperature range of -25ºC to +60ºC
The Powerstax TVR3001 is CE marked for compliance with the LVD 73/23/EEC, complies with the requirements of EN60950, is designed to meet EMC standards MIL-STD-461E tests CE102, RE101 & RE102 and for bump & vibration MIL-STD-810F Method 516.5 Procedure IV & Method 514.5 Procedure 1, Annex A, Category 20, environment designed to meet MIL-STD-810F Method 506.4 Procedure II (blowing sand).
Typical applications for the Powerstax TVR3001 include MILCOTS systems, homeland security, avionics, shipboard and ground systems and mobile/vehicle mounted equipment.