The CPT 4:1 input series meets EN 60950 basic insulation requirements and is UL94 V-0 flammability rated. The module complies with all of the typical industry requirements including no load operation, 2X nominal input voltage transient and pre-biased load startup.
Other features include: fixed-frequency operation, auto-restart OVP, OCP & OTP protections, UVLO, remote sense and +/-10% output voltage trim using industry standard equations. Remote ON/OFF is standard with positive or negative logic options available.
The modules feature a standard 16th brick pinout with dimensions of 1.3” L x 0.9” W (33.02mm x 22.86mm.) It has a maximum height of 0.37″ (9.4mm) which accommodates tight card spacing with minimal airflow blockage of downstream components.