All versions are 8HP wide and are available with either 18 – 36VDC, 36 – 72VDC or autoranging 85 – 264VAC inputs to suit a wide variety of potential applications. 3U versions are rated at 200 or 300W, 6U ones at 350, 400 or 500W. In addition, the +12V output is rated at 5A and the -12V at 1A.
The units feature active power factor correction to achieve a typical power factor of 0.98, and efficiency is greater than 80% at full load. They are hot swappable, have high temperature shutdown with auto recovery, overload, over-voltage and short circuit protection and operate at full load up to 55°C without derating subject to forced air cooling at 250 linear feet/minute. Line regulation is ±0.5%, 3.3V and 5V load regulation ±1%, 5V ripple is 60mV p-p, 3.3V ripple is 90mV p-p.
All front panels are fitted with an EMI gasket and guide pin, protective ground, injector/extractors and keying to conform to IEEE 1101.10/11.