Output currents range from 66 to 303mA and 132 to 600mA for the P and P2 series, respectively.
Key features of the P/P2 series are the wide operating temperature range of -40 to +85°C and isolation voltage of 5200Vdc (for one second) and short-circuit protection. Other electrical specifications of the series include ripple and noise of 200mV (peak-peak maximum) and output voltage tolerances of 5% maximum. Line voltage regulation is 1.2% typical and 15% (3.3 and 5V outputs) and 10% (9, 12 and 15V outputs) maximum.
Available in UL94V-0 rated 7-pin SIP packages, featuring internal surface-mount construction, the devices meet international safety standards including CE EN-60950-1 and CE EN-60601-1.