Accurately monitoring the phase current of motors and BUS voltage fluctuations is essential when providing feedback to the MCUs used in factory automation equipment if they are to achieve high-precision operation. To meet these requirements, Toshiba has equipped the new devices with a delta sigma ADC at the input side that enables the devices to achieve a high level of linearity of 4LSB (typical) @ INL.
TLP7830 and TLP7930 provide a guaranteed Common Mode Transient Immunity of 20kV/µs (typical @VCM=1kV, Ta=25°C), and this enables stable operation in electrically noisy environment ensuring they are particularly suited for motor control applications. The optical barrier guarantees an isolation voltage of 5,000VRMS (minimum). The devices have been designed to support a wide operating temperature range from -40 to +105°C.