These new certified standards allow the SCM5B range to be used for military COTS applications requiring stringent vibration and shock approvals.
The test approvals are as follows :
Random Vibration (Operating) – MIL-STD 202G, Method 214A, Condition 1
Frequency Range : 50-2000Hz, Flat Spectrum
Vibration Intensity : 7.56Grms
Duration : 10 min / axis (X, Y, Z)
Shock (Operating) – MIL-STD-810F, Method 516.5
Pulse Shape : Sawtooth
Test Level : 30G
Duration : 11ms
Orientation : ±X, ±Y, ±Z
Swept Sine Vibration (Operating) – MIL-STD-810G, Method 514.6, Modified
Frequency Range : 10-2000Hz
Vibration Intensity : 5Gp-p
Sweep Rate : 1 octave / min
Orientation : X, Y, Z